TRICOR Coriolis mass flow meters have the best price-quality ratio on the market. The sensitivity of electronics allows for greater measuring range and accuracy at low flow rates. Tricor mass flow meters measure mass flow, capacity consumption, temperature and density simultaneously, replacing several devices.
Accuracy
No maintanance required
Wide range of sizing
Approvals
Specification:
Wermundsen OÜ
Mustamäe tee 55
EE-10620 Tallinn, Estonia
Tel: (+372) 601 4202
wermundsen@wermundsen.ee
TCM325 |
TCM650 |
TCM1550 |
TCM3100 |
TCM5500 |
TCM7900 |
TCM28k |
TCM65k |
|
Flow range (kg/h) |
325 |
650 |
1550 |
3100 |
5500 |
7900 |
28 800 |
65 000 |
Ratio |
100:1 |
100:1 |
100:1 |
100:1 |
100:1 |
100:1 |
100:1 |
100:1 |
Accuracy (% from reading) |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
0 point stability (% from whole range) |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
0.01 |
Repeatability (%) |
0.05% |
0.05% |
0.05% |
0.05% |
0.05% |
0.05% |
0.05% |
0.08% |
Density measurement range |
0 – 4500 kg/m³ |
|||||||
Density measurement accuracy |
± 0.002 kg/ltr |
|||||||
Temperature measurement accuracy |
±1°C ±0.5 % from reading |
|||||||
Process and media parameters |
||||||||
Process connections |
G 1/2”, flanged and tri-clamp |
flanges EN1092, ANSI B16.5, DIN2512 |
||||||
Max. pressure (bar) |
200 bar |
200 bar |
200 bar |
200 bar |
345 bar |
100 bar |
||
Density of measured media |
500 – 2500 kg/m³ |
|||||||
Temperature range media |
-40 ... +125 °C |
-40 ... +100 °C |
||||||
Ambient temperature |
-20 ... +70 °C |
-20 ... +60 °C |
||||||
Storage temperature |
-40 ... +70°C |
|||||||
IP rating |
IP67 |